SARS-CoV-2/influwenza A/influwenza B
Isem tal-prodott
HWTS-RT148-SARS-CoV-2/influwenza A/influwenza B Kit ta' Sejbien Magħqud ta' Aċidu Nukleiku (PCR tal-Fluworexxenza)
Kanal
Isem tal-Kanal | PCR-Mix 1 | PCR-Mix 2 |
Kanal FAM | ġene ORF1ab | IVA |
Kanal VIC/HEX | Kontroll intern | Kontroll intern |
Kanal CY5 | ġene N | / |
Kanal ROX | E ġene | IVB |
Parametri Tekniċi
Ħażna | -18℃ |
Żmien kemm idum tajjeb | 12-il xahar |
Tip ta' kampjun | Tampuni nażofarinġi u tampuni orofarinġi |
Mira | SARS-CoV-2 tliet miri (ġeni Orf1ab, N u E)/influwenza A/influwenza B |
Ct | ≤38 |
CV | ≤10.0% |
LoD | SARS-CoV-2: 300 Kopja/mL virus tal-influwenza A: 500 Kopja/mL virus tal-influwenza B: 500 Kopja/mL |
Speċifiċità | a) Ir-riżultati tat-test inkroċjat urew li l-kit kien kompatibbli mal-koronavirus uman SARSr-CoV, MERSr-CoV, HcoV-OC43, HcoV-229E, HcoV-HKU1, HCoV-NL63, virus respiratorju sinċizjali A u B, virus parainfluwenza 1, 2 u 3, rhinovirusA, B u C, adenovirus 1, 2, 3, 4, 5, 7 u 55, metapneumovirus uman, enterovirus A, B, C u D, virus pulmonari ċitoplasmiku uman, virus EB, virus tal-ħosba Ċitomegalovirus uman, rotavirus, norovirus, virus tal-gattone, virus tal-varicella zoster, Mycoplasma pneumoniae, Chlamydia pneumoniae, Legionella, pertussis, Haemophilus influenzae, Staphylococcus aureus, Streptococcus pneumoniae, Streptococcus pyogenes, Klebsiella pneumoniae, Candida fumigatida tuberkulosi, Candida fumidida tuberculosis ta Ma kienx hemm reazzjoni inkroċjata bejn Pneumocystis yersini u Cryptococcus neoformans. b) Abbiltà kontra l-interferenza: agħżel mucin (60mg/mL), 10% (V/V) demm uman, diphenylephrine (2mg/mL), hydroxymethylzoline (2mg/mL), sodium chloride (li fih preservattiv) (20mg/mL), beclomethasone (20mg/mL), dexamethasone (20mg/mL), flunisone (20μg/mL), triamcinolone acetonide (2mg/mL), budesonide (2mg/mL), mometasone (2mg/mL), fluticasone (2mg/mL), istamina hydrochloride (5mg/mL), α-Interferon (800IU/mL), zanamivir (20mg/mL), ribavirin (10mg/mL), oseltamivir (60ng/mL), pramivir (1mg/mL), lopinavir (500mg/mL), ), ritonavir (60mg/mL), mupirocin (20mg/mL), azithromycin (1mg/mL), ceprotene (40μg/mL) Meropenem (200mg/mL), levofloxacin (10μg/mL) u tobramycin (0.6mg/mL) .Ir-riżultati wrew li s-sustanzi li jinterferixxu fil-konċentrazzjonijiet ta 'hawn fuq ma kellhom l-ebda rispons ta' interferenza għar-riżultati ta 'skoperta ta' patoġeni. |
Strumenti Applikabbli | Applied Biosystems 7500 Sistemi PCR Real-Time Applied Biosystems 7500 Sistemi Fast Real-Time PCR SLAN ®-96P Real-Time PCR Systems QuantStudio™ 5 Sistemi PCR f'ħin reali LightCycler®480 Real-Time PCR sistema LineGene 9600 Plus Real-Time PCR Detection System MA-6000 Ċiklu termali kwantitattiv f'ħin reali BioRad CFX96 Real-Time PCR System BioRad CFX Opus 96 Real-Time PCR System |